Through the use of steel fibre reinforcing, we are able to manufacture our collection wells cost effectively and offer structural performance, not achievable with plastic roto-moulded tanks. This opens up many possibilities to the placement of water storage and retainment vessels in domestic and commercial applications.
Water Tightness
As part of our quality assurance procedures all collection wells remain in examination bed full of water for 28 days to ensure full cure and no leakage.
Load Ratings
As required by Australian Standard AS1546 our collection wells are required to be top-load and side-load tested to specific load requirements.

Lateral Loading CWT 3000L

  • Tank empty – Load applied to straight edges of tank – 10.3kN
  • Tank empty – Load applied to circular ends of tank – 5.05kN
  • Tank filled with water – Load applied to straight edges of tank – 18.2kN
  • Tank filled with water – Load applied to circular ends of tank – 8.95kN
  • Top Loading CWT 3000L

  • Top Load: 510Kg
  • Please contact us for detailed load rating information.

    CWT 10000L with Lid CWT 10000L with Heavy Duty Lid CWT 10000L with Rising Main Pump
    CWT 10000L with Pressure Pump CWT 10000L with Evaporation Chamber
    CWT 10000L with Pressure Pump CWT 10000L with Evaporation Chamber
    CWT 10000L Septic Tank and Rising Main Pump Combo CWT 10000L Septic Tank and Rising Main Pump Combo CWT 10000L Septic Tank